HiPath BizIP connection of standard SIP devices

From Wiki

Jump to: navigation, search

The following devices have been tested with HiPath BizIP.

Starting with V1R4, standard SIP devices can be connected to HiPath BizIP to cover additional user scenarios. The core devices are still the BizIP 410 phones with full feature set. Voice mail with message waiting, DSS keys, central phone book and CTI are not available with standard SIP devices.

For every two BizIP 410 it is possible to connect one standard SIP device. Please find configuration and user hints below.

Contents

optiPoint 150 S

Software versions

Tested optiPoint 150 S software version: V1.45

Installation hints

  • Connect optiPoint 150 S to the LAN and find out its IP address by pressing the menu key and scrolling to 6.Status.
  • Enter this IP Address in your PC Browser and logon as administrator (admin, 123456 as default).
  • Select SIP Setup, SIP Settings and enter the following data:
    • "Registrar IP address or DNS name" = <AD 20 IP>, "Port" = 5060
    • "Server IP address or DNS name" = <AD 20 IP>, "Port" = 5060
    • "SIP Server Typ" = H8000
    • "Phone number" = <unused internal number>
  • For calling to BizIP 410 mailboxes and the group-mailbox by dialling 99, codec G.729 and DTMF-Mode RFC2833 have to be configured:
    • Select Phone SetupCodec > change field "G.72x Select" from "None" to "G.729AB"
    • Select Phone Setup DTMF > Change field "Out Band DTMF" from "None" to "RFC2833"
  • For display of time and date at optiPoint 150 S
    • Select User Localization
    • Set Time Server to "on"
    • Enter Time Server Address e.g. 192.53.103.103
    • select daylight saving and display format
  • For using optiPoint 150 S as teleworking device select authentication, user and password for external subscriber within HiPath BizIP web-based management
    • Set SIP user ID and SIP Password in optiPoint 150 S to the values defined within HiPath BizIP
    • Set STUN Server according your provider e.g. stun.sipgate.net:10000

After reboot the optiPoint 150 S will register at BizIP AD 20 as new subscriber.

Restrictions

  • The HiPath BizIP feature "deflect call" is not supported by optiPoint 150 S.
  • The optiPoint 150 S feature COLP is not supported together with HiPath BizIP.
  • optiPoint 150 S plays no music on hold when in hold state.

optiPoint WL2 professional S

Software versions

Access point for WL2: AP26xx, software version V1 R3.3.4

Tested WL2 software version: R0.55.0 (70.000.55)

Installation hints

WL2 WBM configuration example:

Network
WLAN Security Encryption WPA-PSK (TKIP)
Pre-Shared Key Length: 8 - 63 characters
VPN Settings
VPN Disable

SIP Provider BizIP
Displayed Name SIP 31
User Name 31
Authentication Name 31
Authentication Password (none)

SIP advanced
Message Waiting Server
Enter IP Address 0.0.0.0
Message Waiting Port 0
Local SIP Port 5060
RTP Base Port 5004
Auto Answer Off
Auto Reconnect Off
Session Timer (in sec.) 3600
Registration Timer (in sec.) 3600

Audio Settings Codec G.711
RTP Packet Size Automatic
Silence Suppression no

Location Server
Location Server Disable

Quality of Service
Protocol Settings

DSCP Class for Voice Expedited Forwarding
DSCP Class for Signalling Expedited Forwarding

VLAN Settings
VLAN Mode None

System Settings
Time and Date
Time Zone Offset (hh:mm) (GMT+02:00)

Special configurations
Daylight Saving Time Off
Time Display Mode 24

Set the time and date manually or by means of an SNTP server.
Setting SNTP Manual
Local Time (hh:mm) 13:04

SNTP Server Address
Enter IP Address Enter Name 192.168.178.254

Restrictions

Join call: only via hang up
Transfer call: not supported
Deflect call: not supported

T-Com TC 300 / Pirelli DP-L10 Dual Mode Phones

Software versions

Access point for TC 300/Pirelli: AP26xx, software version V1 R3.3.4

Tested software versions: T-Com D910.0.3.63, Pirelli D910.0.3.98f, Arcor D910.0.3.99c

Installation hints

WLAN Settings: "WAN/WLAN settings/Edit act. settings": "SSID" = <your SID and security settings>

Basic X-Lite setup (no security): "WAN/SIP Settings": "Username" = <unused P2P number>, "Proxy server" = <AD 20 IP>, "Register server" = <AD 20 IP>

Restrictions

Join call: not supported

Conference call: not supported

Transfer call: not supported

Deflect call: not supported

TC 300 does not support codec G.729: Calls to the group-mailbox (magic mailbox) by dialling 99 are not possible.

Unsatisfying battery stand-by performance.

TC 300/T-Com and Toplink (DDI account): Incoming SIP call accepted by TC 300 has one-sided payload. External party does not hear TC 300. Problem does not occur with outgoing calls or Pirelli software.

X-Lite Softclient

Freeware from www.counterpath.com

Software versions

Tested software version: V3.0 Build 39982 and 41150

Installation hints

Basic X-Lite setup (no security): "SIP Account Settings": "Domain" = <AD 20 IP>, "User name" = <unused P2P number>

Important codec issue

X-Lite codec changes (X-Lite problem) during connections have to be prevented with the following workaround:

Dial ***7469 Dial

This will bring up the advanced settings menu.

Filter for "honor"

Double click on the entry and change the value to 1

Save and restart

Restrictions

Transfer call: not supported by X-lite 3.0
Deflect call: not supported by X-lite 3.0
Music on Hold: not supported by X-lite 3.0 - only display message
No HiPath BizIP voice mail reachable from X-lite, due to missing G.729 support

Call transfer and G.729 are available with the commercial version eyeBeam 1.5 basic from CounterPath.

Grandstream BudgetTone-100/200

Homepage on www.grandstream.com

Software versions

Tested software versions: BT100 1.0.8.33, BT200 1.1.4.18

Installation hints

Basic BT100/200 WBM setup (no security): "SIP Server" = <AD 20 IP>, "SIP User ID" = <unused P2P number>

BT100/200 WBM, ADVANCED SETTINGS, "Send DTMF" = via RTP (RFC2833)

Restrictions

Deflect call: not supported

Grandstream HandyTone-286/386

Homepage on www.grandstream.com

Software versions

Tested software versions: HT286 1.0.8.33, HT386 1.0.3.86

Installation hints

Basic HT286/386 WBM setup (no security): "SIP Server" = <AD 20 IP>, "SIP User ID" = <unused P2P number>

Terminal Adapter (TA) phone features

AD 20 WBM, Conn.Settings/Telephony/VoipCallMgmt, "Endpoint-Type" = SIP-Phone

HT286/386 WBM, FXS PORT, "Send DTMF" = via RTP (RFC2833)


Phone features (e.g. Hold, Transfer, Conference) have been tested with Euroset 815/Euroset 2020 analog phone and FLASH KEY time = 600ms


Change Euroset 815 flash time for FLASH KEY

1. Lift handset and press "Speichern" then "#" and enter a digit: 2 = 90ms (def.), 5 = 120ms, 6 = 180ms, 7 = 300ms, 8 = 600ms

2. Press "Speichern" again and hang up.


Change Euroset 2020 flash time for FLASH KEY

1. Lift handset and press "Speichertaste" then "195" and enter a digit: 0 = 90ms (def.), 1 = 120ms, 2 = 270ms, 3 = 375ms, 4 = 600ms

2. Press "Speichertaste" again and hang up.


TA FAX via T.38 protocol

Tested SIP providers: Toplink (DDI account) and Freenet (single account)

AD 20 WBM, Conn.Settings/Telephony/VoipCallMgmt, "Endpoint-Type" = SIP-FAX

HT286/386 WBM, FXS PORT, "FAX Mode" = T.38 (Auto Detect)

FAX tests via SIP/T.38 have been done using HP OfficeJet Modell 635 and Brother FAX-2920

Restrictions

T.38 protocol support is SIP provider dependent.

G.711 FAX is not 100% reliable due to uncertain data transmission (no retransmission).

Grandstream HandyTone-502

Homepage on www.grandstream.com

Software versions

Tested software versions: 1.0.0.77

Installation hints

Basic HT502 WBM setup (no security): "SIP Server" = <AD 20 IP>, "SIP User ID" = <unused P2P number>

Terminal Adapter (TA) phone features

AD 20 WBM, Conn.Settings/Telephony/VoipCallMgmt, "Endpoint-Type" = SIP-Phone

HT502 WBM, FXS PORT1/2, "Send DTMF" = via RTP (RFC2833)


Phone features (e.g. Hold, Transfer, Conference) have been tested with Euroset 815/Euroset 2020 analog phone and FLASH KEY time = 600ms


Change Euroset 815 flash time for FLASH KEY

1. Lift handset and press "Speichern" then "#" and enter a digit: 2 = 90ms (def.), 5 = 120ms, 6 = 180ms, 7 = 300ms, 8 = 600ms

2. Press "Speichern" again and hang up.


Change Euroset 2020 flash time for FLASH KEY

1. Lift handset and press "Speichertaste" then "195" and enter a digit: 0 = 90ms (def.), 1 = 120ms, 2 = 270ms, 3 = 375ms, 4 = 600ms

2. Press "Speichertaste" again and hang up.


TA FAX via T.38 protocol

Tested SIP providers: Vortel (MSN account) and Carpo (MSN account)

AD 20 WBM, Conn.Settings/Telephony/VoipCallMgmt, "Endpoint-Type" = SIP-FAX

HT502 WBM, FXS PORT1/2, "FAX Mode" = T.38 (Auto Detect)

FAX tests via SIP/T.38 have been done using Canon FAX-B155

Restrictions

T.38 protocol support is SIP provider dependent.

G.711 FAX is not 100% reliable due to uncertain data transmission (no retransmission).

Gigaset S450 IP as SIP-Teleworker

Software versions

Tested S450 IP software version: 020970000000 / 041.00

Installation hints

AD20 is connected to Office LAN. S450 IP is connected to Teleworker LAN.

  • Set AD 20 Conn.Settings/Telephony/VoipCallMgmt, "Endpoint-Type" = External Subscriber and select SIP number
  • Set Authentication=YES and set up User/Password

  • Connect S450 IP to Teleworker-LAN, enter IP Address in your PC Browser and logon via System-PIN (0000 as default)
  • Select Einstellungen, Telefonie, Verbindungen
  • Set 1. VoIP-Verbindung = Aktiv, and Gigaset.net = Deaktiviert
  • Select 1. VoIP-Verbindung Bearbeiten and enter the following data:
    • "Verbindungsname oder Rufnummer:" = <external subscriber number>
    • "Anmelde-Name:" = <AD20 user name>
    • "Anmelde-Passwort:" = <AD20 user password>
    • "Benutzer-Name:" = <AD20 external subscriber number>
    • "Angezeigter Name:" = <AD20 external subscriber number>
  • Press "Weitere Einstellungen anzeigen" and enter the following data:
    • "Domäne:" = <AD20 dynDNS ip>
    • "Proxy-Server-Adresse:" = <AD20 dynDNS ip>
    • "Server-Port:" = 5060
    • "Registrar-Server:" = <AD20 dynDNS ip>
    • "Registrar-Server-Port:" = 5060
    • "Anmelde-Refreshzeit:" = 180
    • "Netztwerk/STUN benutzen" = Ja
    • "STUN-Server:" = <STUN server ip> e.g. stun.1und1.de
    • "STUN-Port:" = 3478

S450 IP will now register as Teleworker to BizIP AD 20.

Restrictions

Teleworker call features are limited to Hold and Retrieve. Features Join, Deflect, Transfer or Conference are not supported for Teleworkers at present. Limitation is valid for all Teleworker standard SIP devices.

See also

Personal tools
Information